Tire strength & Bead-unseating (with Longitudinal and Lateral Rigidity) Testing

Product information | ||||||
Model |
GC-YLDT-12 | |||||
Device name | Tire strength/ bead-unseating testing equipment with longitudinal / lateral stiffness | |||||
Introduction | GC-YLDT-12Tire strength / bead-unseating testing machine (with longitudinal / lateral rigidity function), uses the servo motor deceleration drive the ball screw loading respectively to drive the plunger, static loading plate, bead-unseating block and longitudinal and lateral rigidity test platform towards the tire fixed on the spindle, at specified test speed for tire strength test, static load test, bead-unseating resistance test, tire longitudinal stiffness and lateral stiffness of the test. | |||||
Equipment parameters | ||||||
project | parameter | |||||
1.Test tyre | ||||||
Strength, static load test | Passenger car tires, light truck tires and truck tires | |||||
Off loop resistance test | Tubeless tire | |||||
Horizontal, longitudinal rigidity test | Car tire | |||||
Strength static load test tire maximum outer diameter | Φ1500mm | |||||
The maximum section width of the tire in static load test | 400mm | |||||
Off loop resistance test tire maximum outer diameter | Φ1000mm | |||||
The maximum section width of the tire | 400mm | |||||
Transverse, longitudinal stiffness test tire maximum outer diameter | Φ1500mm | |||||
Transverse, longitudinal rigidity test tire maximum section width | 400mm | |||||
Test rim specification | 10″~28″ | |||||
2.Test load | ||||||
Strength, static load test | Max.98kN,Load accuracy:±49N(490N-4900N);±1%(4900N-98KN)。 | |||||
Off loop resistance test | Max.29.4kN,Load accuracy:±29.4N(294N-2940N);±1%(2940N-29.4KN)。 | |||||
Horizontal, longitudinal rigidity test | MAX.2000kg,Load accuracy:Set value±1%。 | |||||
3.Test speed | 50mm/min±1mm/min | |||||
4.Strength test puncture rod diameter | Ф19、Ф32、Ф38 | |||||
5.Off loop resistance test | A、B、C | |||||
6.Weight | about 4.5T | |||||
7.Size(Length ) | about 2400mm(L)×1720mm(W)×3210mm(H) | |||||
8.Electric load | 10KVA | |||||
9.No-load noise | One meter away from the equipment≤85dB |